Huawei Smart SUN2000-450W-P2 Optimizer - General Data
Dimensions (W x H x D): 71 x 138 x 25 mm (2.8 x 5.4 x 1.0 in.)
Weight (including cable): 0.55 kg
Installation part (optional): Grounding plate, grounding clamp, PV module frame plate
Input connector: Staubli MC4
Output connector: Staubli MC4
Length of output cable4: 1.2 m
Operating temperature5: -40 ~ +85 ℃
Humidity range: 0% RH~ 100% RH
Protection class: IP68

Huawei Smart SUN2000-450W-P2 Optimizer - Input
Rated input power1: 450 W
Absolute maximum input voltage: 80 V
MPPT operating voltage range: 10 - 80 V
Max. Input Current: 14.5 A
Max. Efficiency: 99.5 %
Weighted efficiency: 99.0 %
Overvoltage category: II

Huawei Smart SUN2000-450W-P2 Optimizer - Output
Max. Output voltage: 80 V
Max. Output current: 15 A
Output bypass2: Yes
Output voltage switch-off per optimiser30 V
Output impedance at switch-off per optimiser: 1 k ohm ± 10%.

Huawei Smart SUN2000-450W-P2 Optimizer - Output
Max. Output voltage: 80 V
Max. Output current: 15 A
Output bypass2: Yes
Output voltage switch-off per optimiser30 V
Output impedance at switch-off per optimiser: 1 k ohm ± 10%.

Long String Design (Full Optimizer)
SUN2000-2-6-KTL-L1: 4 - 25 | 6,000 W
SUN2000-3-10KTL-M1: 6 - 35 | 10,000 W
SUN2000-12-20KTL-M2: 6 - 35 | 12,000 W
SUN2000-30-40 KTL-M3: 6 - 25 | 12,000 W

Huawei Smart SUN2000-450W-P2 Optimizer - Communication Protocol
Communication protocol: MBUS

Huawei Smart SUN2000-450W-P2 Optimizer - Standards Compliance
Safety: IEC62109-1 (Safety Class II)
RoHS: Yes

Huawei Smart SUN2000-450W-P2 Optimizer - Inverter - Compatibility
Compatible product:
SUN2000-2 / 3 / 3.68 / 4 / 4.6 / 5 / 6 KTL-L1
SUN2000-3 / 4 / 5 / 6 / 8 / 10 KTL-M1
SUN2000-12 / 15 / 17 / 20 KTL-M2
SUN2000-30 / 36 / 40 KTL-M3

Huawei Smart SUN2000-450W-P Optimizer - Notes and Explanations
1 In the STC environment, the rated power of the module must not exceed 1.05 times the input rated power of the optimiser.

2 The power optimiser is bypassed in a string connected to an inverter in operation when it is not working.

3 OVdc output of the power optimiser when the connection to the inverter is disconnected or the inverter is switched off.

4 Enables installation of PV modules in frame/installation/extruded aluminium profiles

5 Fits PV module in landscape and portrait installation.

6 Requires standard 60 cell module to meet minimum inverter start voltage.

7 Full performance refers to the intelligent online design tool.

ATE
Bosch
Brembo
Castrol
Eibach
Elring
Luk
Mobil1
Nissen
Quick Brake
Textar
TRW
Klaxcar
Ina
Bohrmann
Dreissner
Kaltstadt
Hager
Hilmann
Wahkberg
Hartwinn
Reinweg
Kergen
Rottler
Krottendorf
VALEO